Skip to content

Basic Features ​

This page covers basic operations in the main window and the device window. For Quick Send, Text Mark, and other advanced features, see the pages under "Advanced Features".

Main Window ​

After startup, the main window shows a Connect Device button in the center. After you connect a device, its device window appears in the main window.

The menu bar is in the title bar at the top of the main window, between the app icon on the left and the minimize, maximize, and close buttons on the right. It has three menus: Device, Configuration, and Help.

MenuCommandDescription
DeviceConnect Device Connect DeviceOpens the device selector. Choose a serial port or a network device. The Connect Device button in the center of the main window runs the same command.
ConfigurationVariable Management Variable ManagementOpens the variable management window. Variables you define can be inserted into send content and used by plugins. See Global Variables.
ConfigurationProject Configuration Project ConfigurationOpens the project configuration window, where you manage the config files for Quick Send, Text Mark, and other features.
ConfigurationBridge BridgeOpens the data bridge settings. Connect the send and receive endpoints of devices with lines to pass through, monitor, or broadcast data. See Data Bridge.
ConfigurationSettings SettingsOpens the settings window.
HelpOnline Documentation Online DocumentationOpens the online documentation in your browser.
HelpCheck for Updates Check for UpdatesChecks whether a new version is available.
HelpAbout AboutShows the version number and third-party library notices.

Connecting a Device ​

  1. Click Connect Device, then choose the device type in the device selector.
  2. For a serial port, choose the port and serial parameters. For a network device, choose a protocol (UDP, TCP Server, or TCP Client), then enter the IP address and port.
  3. After you finish the settings, confirm to open the device. The device window appears as a new tab in the main window.

If a serial port cannot be opened, the app shows "Unable to open the selected serial port." If a network port cannot be opened, it shows "Unable to open the network port." The serial or network settings from your last successful open are saved and filled in next time.

Opening Several Devices ​

The main window can open several devices at the same time. Each device has its own tab. Click a tab to switch to that device.

Click the close button at the top right of the tab bar to close the current device. This closes the device immediately without a confirmation dialog. Closing the main window closes all open devices.

Device Window ​

This section describes the controls and buttons in the device window.

Tool Panels ​

Some buttons in the right column, such as Quick Send and Text Mark, show or hide their tool panels. A pressed button means its panel is shown.

Receive Area ​

The controls at the top of the receive area set how data is received.

  • Receive Mode: Chooses how received data is parsed.
    • HEX: Shows received data as hexadecimal.
    • Text: Shows received data as text.
    • Text (split by \n): Ends a packet when a newline arrives. This suits devices that send one message per line.
    • JustFloat: Parses received data with the JustFloat protocol.
  • Frame Process: Converts each packet with a script after packet splitting and before display. The options are "Do not process", "Lua script", and "Python script". See Frame Processing Scripts. Frame Process returns to "Do not process" each time you open a device window.
  • Receive Interval: The default is 10 ms, and the range is 1 to 9999 ms. HEX and Text modes split packets by this interval: when the gap between two pieces of data is longer than this value, the earlier piece is shown as one packet. Stream modes do not use the receive interval, so this control is hidden in those modes.

The buttons in the receive area are listed below.

IconButtonDescription
Stop ReceiveStop ReceiveCheckable, off by default. When checked, new data is not shown, is not counted in the receive byte count, and is not passed to plugins or the data bridge. Clear the check to resume receiving.
TimestampTimestamp SplitCheckable, on by default. When checked, each packet is shown with its receive time in the format [HH:mm:ss.zzz] [RX] content.
Auto ScrollAuto Scroll to BottomCheckable, on by default. When checked, the receive area scrolls to the bottom when new data arrives. When unchecked, the scroll position stays where it is.
SplitSplit Send and ReceiveCheckable, off by default. When checked, the receive area has two text boxes side by side: received data on the left and sent data on the right.

Send Area ​

The send area sends data.

  • Input box: Type the content to send. You can use {variableName} placeholders. When the data is sent, each placeholder is replaced with the current value of the variable.
  • Send: Sends the content in the input box. When Timed Send is on, this button changes to Stop.

The buttons in the send area are listed below.

IconButtonDescription
Insert VariableInsert VariableChooses a global variable and inserts it at the cursor in the input box.
Send HistorySend HistoryShows recently sent content. The app keeps up to 20 entries. Click an entry to put it back into the input box.

The send options are listed below.

  • HEX Send: On by default. When checked, the input box content is parsed as hexadecimal, for example 01 03 00 00.
  • Add \r\n: When checked, \r\n is appended to the end of each sent data packet.
  • Checksum: Chooses a checksum algorithm such as Modbus-CRC16, ADD8, or XOR8. The checksum value is appended to the end of the data. The checksum applies only when HEX Send is checked. You can also choose "Lua script" or "Python script" to calculate the checksum. See Checksum Scripts.
  • Timed Send: When checked, the input box content is sent repeatedly at the interval set beside it, in milliseconds. The default interval is 100 ms. While timed sending is running, the input box and these options cannot be changed.

Status Strip ​

The status strip shows:

  • Device identifier: For a serial port, the port name, such as COM3. For a network device, the IP address and port.
  • Connection status: Connected in green, or Disconnected in red.
  • Byte counts: The number of bytes sent and received.
  • Realtime Save: While realtime saving is running, the size written to the file, with a Stop Realtime Save button.
  • Control lines: Serial devices only. RTS, CTS, DTR, DSR, DCD, and RI are shown, and their states update as the control line levels change.

Function Buttons ​

IconButtonDescription
Quick SendQuick SendShows or hides the Quick Send panel. See Quick Send.
Text MarkText MarkShows or hides the Text Mark panel. See Text Mark.
Auto AnswerAuto AnswerShows or hides the Auto Answer panel. See Auto Answer.
Data AnalysisData AnalysisShows or hides the Data Analysis panel. See Data Analysis.
Process ExecutionProcess ExecutionShows or hides the Process Execution panel. See Process Execution.
Plugin ListPlugin ListShows or hides the plugin list. Use it to add plugins to the display area. See Plugin Overview.
Python ScriptPython ScriptShows or hides the Python run panel for running Python scripts. See Python Process.
Serial ConfigSerial ConfigSerial devices only. Opens the serial parameter settings. See below.
Realtime SaveRealtime SaveOpens the realtime save settings. After you click Start Saving, sent and received data is written to a file continuously.
Save DataSave DataSaves the content of the receive and send areas as a txt file. The default location is the desktop. When send and receive are split, you choose one file for received data and one for sent data.
Clear WindowClear WindowClears the content of the receive and send areas and resets the byte counts. Data shown in visualization plugins is also cleared.
Close DeviceClose DeviceShows a confirmation dialog. After you confirm, the app stops any timed or quick sending in progress and closes the device.

Serial Parameter Settings ​

Click Serial Config to open the serial parameter settings. You can change the port, baud rate, data bits, parity, stop bits, flow control, read buffer, and control lines (DTR, RTS, and whether to reconnect automatically when DCD is lost).

  • Click Apply to apply the changes to the current serial port. The port stays the same, and the device window stays open.
  • Click Close Port to release the serial port without closing the device window. The button then changes to Open Port, and you can click it to reopen the port.

Saved Settings ​

The app saves the following settings by device name. When you open the same device again, these settings are restored.

  • Receive mode and receive interval.
  • Split Send and Receive, Timestamp Split, and Auto Scroll to Bottom.
  • Send input content, timed send interval, Add \r\n, and send history.

Stop Receive and Frame Process are not saved. Stop Receive is cleared each time you open a device, and Frame Process returns to "Do not process."